A hands-on Quality First” Low Pressure Steam Boiler Water Management Program program includes, but is not limited to the following:

  1. Programming, calibration and cleaning of feed equipment and monitoring controllers.
  2. A unit specific (by-pass feeder or treatment metering pump) logbook is maintained with setting and dosage rates.
  3. The feed station is cleaned every service visit. Any unsightly or hazardous conditions that may appear must be reported to Purity Labs, Inc immediately. A representative will respond in 24 hours.
  4. Visual inspection and documentation of all accessible system components. This includes the following:
    Internal inspection (when hatches are open)
    boilerFeedwater tanks and pumps
    Site glasses (cracks, turbidity and surging)
    Softeners
    Steam traps
    Dearators
    Blowdown valves
    Condensate receiver tanks
    Heat exchangers (ensures tube integrity)
  5. The treatment blends provided are guaranteed not to damage the low pressure steam boiler system; when applied properly and as instructed.
    BWT-NP– A multi-functional powdered corrosion inhibitor for low pressure heating boilers and closed recirculating systems. A protective film is provided for ferrous metals and may reduce oxygen pitting in boilers and pipe surfaces. BWT-NP is added to the system through a bypass feeder, by directly pumping the dissolved solution into the boiler or by using a chemical feed pump.
    BWT-N – A multi-functional liquid corrosion inhibitor for closed recirculation systems and low pressure steam boilers. A protective passivating film is provided to ferrous and non- ferrous metals. It also aids in preventing oxygen pitting and sequestering hardness in recirculating water. BWT-N is added to the system through a bypass feeder, by directly pumping the solution into the boiler or by using a chemical feed pump. It is excellent for use in closed recirculating systems when applied automatically with a falling set point conductivity controller.
  6. Analysis of unit and system. The results will be maintained in the unit specific logbook for review by all concerned personnel. All recommended treatment parameters are properly maintained.
  7. Detailed service report noting repairs, actions and field analysis results. The report is discussed by the technician with all concerned parties before departing the site.
  8. Value- added services (as applicable). All treatments are provided with each service visit.

Contact Purity to labs to schedule or learn more.